HT-7超导托卡马克上时间分辨中子注量率测量
Time-resolved Neutron Flux Density Measurement on HT-7 Superconducting Tokamak
-
摘要: 本文介绍了HT 7超导托卡马克上的时间分辨中子注量率测量系统。在高参数放电状态下,计算得到中子产额在108 s-1量级,在靠近装置边上的中子注量率处于 102 cm-2 ·s-1 量级,因此,选择 BF3正比计数管作为探测器。经过多次实验,测量系统运行稳定可靠,测量得到的中子注量率和估算得到的中子注量率在误差范围内一致。Abstract: The time-resolved neutron flux density measurement system on HT-7 Tokamak is presented in the paper. When the machine is operated in high performance mode, the total neutron yield is estimated to be about 10~8 s~(-1), and the neutron flux density near the vacuum vessel is about 10~2 cm~(-2)·s~(-1). Therefore, BF_3 proportional counter based system was constructed and successfully implemented on HT-7. The measurement system works stably during a series of experiments. The measured neutron flux density is in agreements with that from the numerical estimation.
下载: