CHEN YUHUA;XIE JUN;ZHANG FULIANG;LI HUIJUN;XU QIAN Institute of Atomic Energy, P.O. Box 275, Beijing. A STUDY ON STABILITY OF FLOW GAS PRESSURE STABILIZING SYSTEM[J]. Atomic Energy Science and Technology, 1986, 20(3): 367-367. DOI: 10.7538/yzk.1986.20.03.0367
Citation: CHEN YUHUA;XIE JUN;ZHANG FULIANG;LI HUIJUN;XU QIAN Institute of Atomic Energy, P.O. Box 275, Beijing. A STUDY ON STABILITY OF FLOW GAS PRESSURE STABILIZING SYSTEM[J]. Atomic Energy Science and Technology, 1986, 20(3): 367-367. DOI: 10.7538/yzk.1986.20.03.0367
  • The flow gas pressure stabilizing system is widely used in the PPAC, lowpressure proportional chamber and focal plate detector. A flow gas pressure stabi-lizing system based on Cartesian diver type of manostat has been built and it's pressure stability is 0.3%. The operational condition of the Cartesian diver typeof manostat and the dependence of pressure stability on tempreture have beenstudied.