JIANG SONGSHENG;MA TIEJUNG;JIANG SHAN;LI YAOHUA;YU JINHUAI China Institute of Atomic Energy, P. O. Box 275, Beijing. AN AMS ELECTROSTATIC DEFLECTOR[J]. Atomic Energy Science and Technology, 1991, 25(4): 29-29. DOI: 10.7538/yzk.1991.25.04.0029
Citation: JIANG SONGSHENG;MA TIEJUNG;JIANG SHAN;LI YAOHUA;YU JINHUAI China Institute of Atomic Energy, P. O. Box 275, Beijing. AN AMS ELECTROSTATIC DEFLECTOR[J]. Atomic Energy Science and Technology, 1991, 25(4): 29-29. DOI: 10.7538/yzk.1991.25.04.0029
  • The design,set-up and test of an electrostatic deflector used in the accelera-tor mass spectrometer(AMS)are described.The main characteristics of electro-static deflector are as follows:The deflection angle is 15°.The radius of curva-ture and length is 360 cm and 100 cm,respectively.The gap between the electrodesis 3 cm.The positive and negative voltage on the two electrodes reach 92.4 kVand 80 kV.respectively,and the electric field is 57.5 kV/cm.