ZHANG PILU (China Institute of Alomci Energy, P. O. Bor 275, Beijing, 102413). DETERMINATION OF ~(147)Pm IN HIGH-LEVEL LIQUID WASTE[J]. Atomic Energy Science and Technology, 1992, 26(5): 81-81. DOI: 10.7538/yzk.1992.26.05.0081
Citation: ZHANG PILU (China Institute of Alomci Energy, P. O. Bor 275, Beijing, 102413). DETERMINATION OF ~(147)Pm IN HIGH-LEVEL LIQUID WASTE[J]. Atomic Energy Science and Technology, 1992, 26(5): 81-81. DOI: 10.7538/yzk.1992.26.05.0081

DETERMINATION OF ~(147)Pm IN HIGH-LEVEL LIQUID WASTE

  • Determination method of ~(147)Pm in high-level liquid waste is set up. The method is composed of extraction RE and Am and Cm from 0.1 mol/I HNO_3 aqueous solution containing samplc with 0.5 mol/l HDEHP-η-heptane, reextraction with 5.5 mol/l HNO_3, subsequently chromatography with a column filled HDEHP-levextrel for separation of RE and Am and Cm when 0.07 mol/l DTPA-1 mol/l lactic acid(pH3. 12) is used as eluant and HPLC for separating ~(147)Pm from other rare earths when α-HIBA was used as eluant. The radioactivity of ~(147)Pm is measured by liquid scintillatin counter.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return