CAO SHENGQUAN;YANG JICAI;LI JIANJUN;DONG ZHIJUAN;REN JUYAN;ZHANG PINYUAN China Institute of Atomic Energy, P. O. Box 275, Beijing, 102413. RESEARCH ON LEAKAGE DETECTION OF NUCLEAR POWER STATION PRIMARY LOOP[J]. Atomic Energy Science and Technology, 1993, 27(4): 336-336. DOI: 10.7538/yzk.1993.27.04.0336
Citation: CAO SHENGQUAN;YANG JICAI;LI JIANJUN;DONG ZHIJUAN;REN JUYAN;ZHANG PINYUAN China Institute of Atomic Energy, P. O. Box 275, Beijing, 102413. RESEARCH ON LEAKAGE DETECTION OF NUCLEAR POWER STATION PRIMARY LOOP[J]. Atomic Energy Science and Technology, 1993, 27(4): 336-336. DOI: 10.7538/yzk.1993.27.04.0336
  • The paper describes a system concerning the leakage of nuclear power station primary loop. Thesensor of leak--detection system is a special humidity--sensitive element. In this system,the collection andtreatment of detected data,and the alarm of leakage are controlled by a simple board computer. Thethree parameters A, B and C are set up in this system, and the alarm will give out when signal surpassesvalues of B and C at the same time. The effects of environment humidity and temperature on collectionof detected data are considered, and the alarm of leakage is reliable. When the leakage rate of water at320℃ and 12. 2 MPa is 0.3g/min, the alarm signal will sent out within 5s.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return