SUN Bao gen, XU Hong liang, HE Duo hui, WANG Jun hua, LU Ping (University of Science and Technology of China, Hefei 230029, China). Measurement and Correction of Chromaticity in Hefei Light Source[J]. Atomic Energy Science and Technology, 2001, 35(2): 158-158. DOI: 10.7538/yzk.2001.35.02.0158
Citation: SUN Bao gen, XU Hong liang, HE Duo hui, WANG Jun hua, LU Ping (University of Science and Technology of China, Hefei 230029, China). Measurement and Correction of Chromaticity in Hefei Light Source[J]. Atomic Energy Science and Technology, 2001, 35(2): 158-158. DOI: 10.7538/yzk.2001.35.02.0158
  • The measurement and correction of chromaticity for Hefei light source is introduced. The natural chromaticity is obtained by detecting the variation of the betatron tune with the main dipole field strength. The correction chromaticity is obtained by detecting the variation of the betatron tune with the RF frequency. The theoretic analysis and formula for the two methods is given. The measurement results of chromaticity are given.