LIAO Yi xiang, QIU Sui zheng, GUO Yu jun, JIA Dou nan (Department of Nuclear Engineering, Xi'an Jiaotong University, Xi'an 710049, China). Heat Removed Ability and Its Influencing Factors Analysis on Residual Heat Removed System of 200 MW Nuclear Heating Reactor[J]. Atomic Energy Science and Technology, 2001, 35(5): 436-436. DOI: 10.7538/yzk.2001.35.05.0436
Citation: LIAO Yi xiang, QIU Sui zheng, GUO Yu jun, JIA Dou nan (Department of Nuclear Engineering, Xi'an Jiaotong University, Xi'an 710049, China). Heat Removed Ability and Its Influencing Factors Analysis on Residual Heat Removed System of 200 MW Nuclear Heating Reactor[J]. Atomic Energy Science and Technology, 2001, 35(5): 436-436. DOI: 10.7538/yzk.2001.35.05.0436

Heat Removed Ability and Its Influencing Factors Analysis on Residual Heat Removed System of 200 MW Nuclear Heating Reactor

  • The 200 MW NHR(nuclear heating reactor) RHRS(residual heat removed system) is numerically simulated by one dimension fluid dynamics model. The heat removed ability of 200 MW NHR RHRS and its influencing factors are analyzed. The area of air condenser and the height of air cooling tower in RHRS are the main factors influencing the residual heat removed ability, the height difference between the main heat exchanger and air condenser is the secondary factor.