XU Hong-liang, LI Jing-yi, SUN Bao-gen, WANG Lin, LI Wei-min, LIU Zu-ping, HE Duo-hui(National Synchrotron Radiation Laboratory, University of Science and Technology of China,P.O.Box 6022, Hefei 230029, China). Electron Equilibrium Orbit Adjustment and Closed Orbit Correction in Hefei Electron Storage Ring[J]. Atomic Energy Science and Technology, 2003, 37(1): 1-1. DOI: 10.7538/yzk.2003.37.01.0001
Citation: XU Hong-liang, LI Jing-yi, SUN Bao-gen, WANG Lin, LI Wei-min, LIU Zu-ping, HE Duo-hui(National Synchrotron Radiation Laboratory, University of Science and Technology of China,P.O.Box 6022, Hefei 230029, China). Electron Equilibrium Orbit Adjustment and Closed Orbit Correction in Hefei Electron Storage Ring[J]. Atomic Energy Science and Technology, 2003, 37(1): 1-1. DOI: 10.7538/yzk.2003.37.01.0001
  • The measurement results of both the magnet field center of quadrupole magnet and the closed orbit distortion correction of Hefei electron storage ring are introduced in the paper. Especially, in the process of closed orbit correction, the electron beam equilibrium orbit is shifted to the center orbit of Hefei storage ring by monitoring the closed orbit distortion due to momentum spread. And the electron injection, accumulating and operation on the center equilibrium orbit are realized.