LI Qiang1, YANG Jian-hui2, ZHOU Yuan1, LI Qing1(1.Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100080, China;2.Department of Physics, Graduate School, Chinese Academy of Sciences, Beijing 100039, China). Study on the Critical Heat Flow Rate of Hydrogen Thermosyphon in Cold Neutron Sources[J]. Atomic Energy Science and Technology, 2003, 37(1): 76-76. DOI: 10.7538/yzk.2003.37.01.0076
Citation: LI Qiang1, YANG Jian-hui2, ZHOU Yuan1, LI Qing1(1.Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100080, China;2.Department of Physics, Graduate School, Chinese Academy of Sciences, Beijing 100039, China). Study on the Critical Heat Flow Rate of Hydrogen Thermosyphon in Cold Neutron Sources[J]. Atomic Energy Science and Technology, 2003, 37(1): 76-76. DOI: 10.7538/yzk.2003.37.01.0076
  • A simple method is established which can determine the size of hydrogen thermosyphon in cold neutron sources. It is showed that the critical heat flow rate is 3 kW when the inner diameter of outside pipe is 54 mm and the inner diameter of inner pipe is 21 mm. 