QIAO Lu-cheng1,2, XU Jia-yun1, BAI Li-xin1, ZHANG Yi-yun1(1.College of Physical Science and Technology, Sichuan University, Chengdu 610064, China;2.China Academy of Engineering Physics, Mianyang 621900, China). Verifying the Criticality Calculation Code CHMCK-Ⅲ With the Benchmark Experiments and MCNP-4B Code[J]. Atomic Energy Science and Technology, 2003, 37(6): 548-548. DOI: 10.7538/yzk.2003.37.06.0548
Citation: QIAO Lu-cheng1,2, XU Jia-yun1, BAI Li-xin1, ZHANG Yi-yun1(1.College of Physical Science and Technology, Sichuan University, Chengdu 610064, China;2.China Academy of Engineering Physics, Mianyang 621900, China). Verifying the Criticality Calculation Code CHMCK-Ⅲ With the Benchmark Experiments and MCNP-4B Code[J]. Atomic Energy Science and Technology, 2003, 37(6): 548-548. DOI: 10.7538/yzk.2003.37.06.0548
  • Using four fast benchmark experiment data and calculation results of MCNP4B code, checking calculation of the CHMCKⅢ code is performed. The results from calculated and experimental measurement show that CHMCKⅢ code is applicable to the criticality safety calculation for nuclear systems.