DUAN Shi-lin, DAI Jun-long, ZENG He-rong. Measurements of Prompt Neutron Decay Constant for 300# Research Reactor[J]. Atomic Energy Science and Technology, 2007, 41(3): 321-324. DOI: 10.7538/yzk.2007.41.03.0321
Citation: DUAN Shi-lin, DAI Jun-long, ZENG He-rong. Measurements of Prompt Neutron Decay Constant for 300# Research Reactor[J]. Atomic Energy Science and Technology, 2007, 41(3): 321-324. DOI: 10.7538/yzk.2007.41.03.0321

Measurements of Prompt Neutron Decay Constant for 300# Research Reactor

  • The prompt neutron decay constant was measured by using reactor noise technology at delayed criticality for 300# pool research reactor. The reactor core uses irradiated low-enrichment fuel loading. The prompt neutron decay constant is obtained from nonlinear least-squares fitting of the cross-power spectral densities measured between two detectors placed adjacent to the core. The measured prompt neutron decay constant αc at delayed criticality with a power of 4 kW is (83.4±0.7) s-1.