Influence and Correction of 220Rn to Radon Measurement for Radtrak Detector
-
Graphical Abstract
-
Abstract
The Radtrak detector used in Gansu investigation was researched and developed. As a high permeable membrane filter for the detector, 220Rn enters detector with 222Rn during exposure period. Gansu cave and traditional dwellings constructed with loam bricks had a high level of 220Rn, and the measurement results of 222Rn were 2-3 times higher than the actual level due to the influence from 220Rn. The detector was improved by decreasing air exchange rate. Improved Radtrak-R-T detector can effectively distinguish 222Rn and 220Rn, and measure the both simultaneously. According to the sensitivities of the detector to 222Rn and 220Rn as well as the 220Rn concentration in the room, a correction way for the data of Gansu investigation was established,and the corrected data were compared with the actual measurement results in this area.
-
-