Seismic Analysis for Discharging Heat Exchanger of Chemical and Volume Control System
-
Graphical Abstract
-
Abstract
A finite element model for chemical and volume control system(RCV) discharging heat exchanger was set up to take seismic analysis by finite element method. The loads include weight, pressure, temperature, pipe load and earthquake. The result was evaluated by RCC-M and ASME. The results of evaluation indicate that the design of RCV discharging heat exchanger is satisfied with the requirement of standard.
-
-