WANG Yi-yuan, LU Wu, REN Di-yuan, ZHENG Yu-zhan, GAO Bo, LI Peng-wei, YU Yue. Total Dose Effect of 10-bit Bipolar D/A Converter Under Different 60Co γ Dose Rates[J]. Atomic Energy Science and Technology, 2009, 43(10): 951-955. DOI: 10.7538/yzk.2009.43.10.0951
Citation: WANG Yi-yuan, LU Wu, REN Di-yuan, ZHENG Yu-zhan, GAO Bo, LI Peng-wei, YU Yue. Total Dose Effect of 10-bit Bipolar D/A Converter Under Different 60Co γ Dose Rates[J]. Atomic Energy Science and Technology, 2009, 43(10): 951-955. DOI: 10.7538/yzk.2009.43.10.0951

Total Dose Effect of 10-bit Bipolar D/A Converter Under Different 60Co γ Dose Rates

  • In order to find the responses of digital-to-analog (D/A) converters in ion-izing radiation environment, total dose effect and room-temperature annealing behavior of a 10-bit bipolar D/A converter irradiated by different 60Co γ dose rates were investigated. The D/A converter is quite sensitive to dose rates, and its functions are normal at high dose rate irradiation. While under low-dose-rate case, it works out of the way and many parameters go beyond its permitted range. Thus, it exhibits an enhanced low-dose-rate sensitivity effect. Finally, possible mechanism was discussed based on the space charge model.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return