CHEN Lian, CHANG Hua-jian, LI Yu-quan, YE Zi-shen, QIN Ben-ke. Analysis on Working Pressure Selection of ACME Integral Test Facility[J]. Atomic Energy Science and Technology, 2011, 45(10): 1215-1220. DOI: 10.7538/yzk.2011.45.10.1215
Citation: CHEN Lian, CHANG Hua-jian, LI Yu-quan, YE Zi-shen, QIN Ben-ke. Analysis on Working Pressure Selection of ACME Integral Test Facility[J]. Atomic Energy Science and Technology, 2011, 45(10): 1215-1220. DOI: 10.7538/yzk.2011.45.10.1215

Analysis on Working Pressure Selection of ACME Integral Test Facility

  • An integral effects test facility, advanced core cooling mechanism experiment facility (ACME) was designed to verify the performance of the passive safety system and validate its safety analysis codes of a pressurized water reactor power plant. Three test facilities for AP1000 design were introduced and review was given. The problems resulted from the different working pressures of its test facilities were analyzed. Then a detailed description was presented on the working pressure selection of ACME facility as well as its characteristics. And the approach of establishing desired testing initial condition was discussed. The selected 9.3 MPa working pressure covered almost all important passive safety system enables the ACME to simulate the LOCAs with the same pressure and property similitude as the prototype. It’s expected that the ACME design would be an advanced core cooling integral test facility design.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return