YIN Jian, PENG Shu-ming, LONG Xing-gui, ZHOU Xiao-song, LI Hai-rong. Progress of Research in Cryogenic Target Characterization Using Backlit Shadowgraph[J]. Atomic Energy Science and Technology, 2012, 46(7): 850-854. DOI: 10.7538/yzk.2012.46.07.0850
Citation: YIN Jian, PENG Shu-ming, LONG Xing-gui, ZHOU Xiao-song, LI Hai-rong. Progress of Research in Cryogenic Target Characterization Using Backlit Shadowgraph[J]. Atomic Energy Science and Technology, 2012, 46(7): 850-854. DOI: 10.7538/yzk.2012.46.07.0850

Progress of Research in Cryogenic Target Characterization Using Backlit Shadowgraph

More Information
  • The equipment of visible light backlit shadowgraph was built, and 0.7-4.6 μm resolution corresponding to 4-30 cm measured distance was acquired. The target in sample room could be accurately fixed within 0.1 mm. A backlit shadowgraph technique was developed. The different resolution shadowgraphs of plastic and glass targets were gained using this technique. The precise measurement and calculation method were built for studying DD/DT ice thickness by gaining the ray energy density image and ray trace model of target. The research detection using shadowgraph and ray interfere technique together could obtain a method of nondestructive measure refractive index of plastic targets. The result shows that the backlit shadowgraph is valid for diagnosing transparent cryogenic target parameter.
  • [1]
    NIKITENKO A I, TOLOKONNIKOV S M. Optical ‘tomography’ of 2-layered targets: 3D parameters reconstruction from shadow images[J]. Fusion Sci Technol, 2007, 51(8): 705-716.
    [2]
    KOCH J A, BERNAT T P, COLLINS G W, et al. Numerical ray trace verification of optical diagnostics of ice surface roughness for inertial confinement fusion experiments[J]. Fusion Sci Technol, 2003, 43(1): 55-65.
    [3]
    KOCH J A, BERNAT T P, COLLINS G W, et al. Quantitative analysis of backlit shadowgraphy as a diagnostic of hydrogen ice surface quality in ICF capsules[J]. Fusion Sci Technol, 2000, 38(2): 124-130.
    [4]
    EDGELL D H, CRAXTON R S, ELASKY L M, et al. Three-dimensional characterization of cryogenic target ice layer using multiple shadowgraph views[J]. Fusion Sci Technol, 2006, 49(7): 616-625.
    [5]
    GILLOT F, CHOUX A, JEANNOT L, et al. Characterization of the DT layer of ICF target by optical techniques[J]. Fusion Sci Technol, 2006, 51(7): 626-634.
    [6]
    WITTMAN M D, HARDING D R. Performance and capabilities of the cryogenic fill-tube-target test facility at LLE[R]. USA: University of Rochester Laboratory for Laser Energetic, 2008.
    [7]
    郑永明, 李秀芳, 赵朝康. 激光聚变靶中氘氚燃料的测量[J]. 强激光与粒子束,1989,1(1):71-75. ZHENG Yongming, LI Xiufang, ZHAO Chaokang. Measurements of fuel content in laser fusion targets[J]. High Power Laser and Particle Beams, 1989, 1(1): 71-75(in Chinese).
    [8]
    尹剑,彭述明,龙兴贵. 背光成像技术在DT冷冻靶研制中的应用[J]. 低温工程,2009,172(6):14-17. YIN Jian, PENG Shuming, LONG Xinggui. Application of shadowgraph in DT cryogenic target development[J]. Cryogenics, 2009, 172(6): 14-17(in Chinese).

Catalog

    Article views (466) PDF downloads (1092) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return