CHEN Xiao-tong, QUAN Ying, WANG Yang, FU Gen-na, LIU Bing, TANG Ya-ping. Treatment of Reactive Process Wastewater With High-Level Ammonia by Blow-off Method[J]. Atomic Energy Science and Technology, 2012, 46(增刊): 133-136. DOI: 10.7538/yzk.2012.46.suppl.0133
Citation: CHEN Xiao-tong, QUAN Ying, WANG Yang, FU Gen-na, LIU Bing, TANG Ya-ping. Treatment of Reactive Process Wastewater With High-Level Ammonia by Blow-off Method[J]. Atomic Energy Science and Technology, 2012, 46(增刊): 133-136. DOI: 10.7538/yzk.2012.46.suppl.0133

Treatment of Reactive Process Wastewater With High-Level Ammonia by Blow-off Method

  • The ceramic UO2 kernels for nuclear fuel elements of high temperature gas cooled reactors were prepared through sol-gel process with uranyl nitrate, which produces process wastewater containing high-level ammonia and uranium. The blow-off method on a bench scale was investigated to remove ammonia from reactive wastewater. Under the optimized operating conditions, the ammonia can be removed by more than 95%, with little reactive uranium distilled. The effects of pH, heating temperature and stripping time were studied. Static tests with ion-exchange resin indicate that ammonia removal treatment increases uranium accumulation in anion exchange resin.