XU Hong. Study on Mitigation Strategy of AP1000 Spent Fuel Pool Exterior Disaster[J]. Atomic Energy Science and Technology, 2012, 46(增刊): 473-478. DOI: 10.7538/yzk.2012.46.suppl.0473
Citation: XU Hong. Study on Mitigation Strategy of AP1000 Spent Fuel Pool Exterior Disaster[J]. Atomic Energy Science and Technology, 2012, 46(增刊): 473-478. DOI: 10.7538/yzk.2012.46.suppl.0473

Study on Mitigation Strategy of AP1000 Spent Fuel Pool Exterior Disaster

  • After Fukushima nuclear accident, much attention has been paid to the safety of the spent fuel pool (SFP). AP1000 spent fuel pool cooling system (SPS) is not a safety related system. It is not designed for design basis accident. But the safety of SFP in exterior disaster and severe accident is very important. The extensive damage mitigation guidelines (EDMG) of NEI to AP1000 SFP accident mitigation was studied, including internal strategy and external strategy. The results are useful for design AP1000 nuclear power plant and the mitigation when SFP exterior disaster happens.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return