Monte-Carlo Simulation of Intensity of Tritium Lamp
-
Graphical Abstract
-
Abstract
Using Monte-Carlo method, physical parameters affecting the intensity of tritium lamp, such as gas pressure and tube diameter, were studied based on glass tube model. The calculation results are in good agreement with that provided by other -researchers. This simulation method can be an effective way to design and optimize tritium lamp.
-
-