LI Xian-li, YIN Guo-hui, MA Huai-cheng, FENG Tian-cheng, TIAN Yan-jie, CHENG Zhi-wei, SUN Gao-feng, SHEN Mao-quan. Analytic Method for Geometrical Parameter Correction of Planar HPGe Detector[J]. Atomic Energy Science and Technology, 2013, 47(10): 1883-1887. DOI: 10.7538/yzk.2013.47.10.1883
Citation: LI Xian-li, YIN Guo-hui, MA Huai-cheng, FENG Tian-cheng, TIAN Yan-jie, CHENG Zhi-wei, SUN Gao-feng, SHEN Mao-quan. Analytic Method for Geometrical Parameter Correction of Planar HPGe Detector[J]. Atomic Energy Science and Technology, 2013, 47(10): 1883-1887. DOI: 10.7538/yzk.2013.47.10.1883

Analytic Method for Geometrical Parameter Correction of Planar HPGe Detector

More Information
  • A numerical integration formula was introduced to calculate the response of planar HPGe detector to photons emitted from point source. Then the formula was used to correct the geometrical parameter of planar HPGe detector. 241Am and 137Cs point sources were placed at a certain distance (1-20 cm) away from entrance window to get the corresponding detection efficiency. The detection parameters were calculated in weighted least square fitting using the formula with the experimental efficiencies as formula results. This correction method was accurate and timesaving. The simulation result from MCNP using the corrected parameters shows that the relative deviations between simulation and experimental efficiencies are less than 1% for 59.5 and 661.6 keV photons with the distance of 1-20 cm.
  • [1]
    SALGADO C M, CONTI C C, BECKER P H B. Determination of HPGe detector response using MCNP5 for 20-150 keV X-rays[J]. Applied Radiation and Isotopes, 2006, 64(6): 700-705.
    [2]
    HELMER R G, HARDY J C, IACOB V E, et al. The use of Monte Carlo calculations in the determination of a Ge detector efficiency curve[J]. Nuclear Instruments and Methods in Physics Research A, 2003, 511(3): 360-381.
    [3]
    LU S R, BENTO J, CARVALHAL G, et al. Parameter optimization of a planar BEGe detector using Monte Carlo simulations[J]. Nuclear Instruments and Methods in Physics Research A, 2010, 623(3): 1014-1019.
    [4]
    ABBAS M I. Analytical formula for well-type NaI(Tl) and HPGe detectors efficiency computation[J]. Applied Radiation and Isotopes, 2001, 559(2): 245-252.
    [5]
    X-ray and gamma-ray standards for detector calibration, IAEA-TECDOC-619[R]. Vienna: IAEA, 1991.
    [6]
    HUBBELL J H, SELTZER S M. Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients from 1 keV to 20 MeV for elements Z=1 to 92 and 48 additional substances of dosimetric interest, NISTIR 5632[R]. USA: NIST, 1995.
    [7]
    CAN C, BILGICI S Z. An investigation of X-ray escape for a HPGe detector[J]. X-Ray Spectrometry, 2003, 32(4): 276-279.

Catalog

    Article views (217) PDF downloads (950) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return