LI Da, ZHANG Wen-shou, JIANG Xin-biao, ZHONG Yun-hong, YU Qing-yu, ZHANGSUN Yong-gang, MIAO Liang-liang, MA Yan, ZHU Guang-ning, ZHANG Qiang, SU Chun-lei, YU Xiao-ren, SONG Xiao-jing. Parameter Measurement for Radiation Field of Large Space Neutron Irradiation Platform in Xi’an Pulsed Reactor[J]. Atomic Energy Science and Technology, 2014, 48(7): 1243-1249. DOI: 10.7538/yzk.2014.48.07.1243
Citation: LI Da, ZHANG Wen-shou, JIANG Xin-biao, ZHONG Yun-hong, YU Qing-yu, ZHANGSUN Yong-gang, MIAO Liang-liang, MA Yan, ZHU Guang-ning, ZHANG Qiang, SU Chun-lei, YU Xiao-ren, SONG Xiao-jing. Parameter Measurement for Radiation Field of Large Space Neutron Irradiation Platform in Xi’an Pulsed Reactor[J]. Atomic Energy Science and Technology, 2014, 48(7): 1243-1249. DOI: 10.7538/yzk.2014.48.07.1243

Parameter Measurement for Radiation Field of Large Space Neutron Irradiation Platform in Xi’an Pulsed Reactor

  • The large space neutron irradiation platform in Xi’an Pulsed Reactor was built in 2010. The designed parameters, measurement method and experimental result of radiation field of the experiment platform were introduced in the paper. With a prior spectrum calculated by Monte-Carlo method, the neutron spectra of the experiment platform were measured by using multiple-foil activation technique, and unfolded with genetic algorithm (GA). The unfolding result of GA is in accordance well with the result of SAND-Ⅱ method, and the validity of GA was proved. γ-ray absorbed dose rate was measured by using thermoluminescent dosimeters. The results show that the radiation field parameter of the experiment platform meets the design requirement.