XIA Wen, YE Hong-sheng, LIN Min, XU Li-jun, CHEN Ke-sheng, CHEN Yi-zhen. Investigation of Self-indicating Radiation Personal Dosimeter[J]. Atomic Energy Science and Technology, 2014, 48(7): 1321-1324. DOI: 10.7538/yzk.2014.48.07.1321
Citation: XIA Wen, YE Hong-sheng, LIN Min, XU Li-jun, CHEN Ke-sheng, CHEN Yi-zhen. Investigation of Self-indicating Radiation Personal Dosimeter[J]. Atomic Energy Science and Technology, 2014, 48(7): 1321-1324. DOI: 10.7538/yzk.2014.48.07.1321

Investigation of Self-indicating Radiation Personal Dosimeter

  • A self-indicating radiation personal dosimeter was investigated using radiation sensitive material diacetylene monomer PCDA, which was a component of the polymerization system. The substrate material, solvent, sensitive material, solution temperature, thickness of film and the preparation method were studied. The dosimeter colour changes from white to blue when exposed 0.1-2.5 Gy, and the linearly dependent coefficient of the exposure response is 0.999 8, the stability of absorbency in two weeks after exposure is testified well. It can be used as self-indicating radiation alert personal dosimeter.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return