LI Meng, YIN Yan-peng, RONG Ru, XIANG Wei-ling. Development and Application of Reactivity Measurement System With Inverse Kinetic Method on Fast Neutron Critical Facility[J]. Atomic Energy Science and Technology, 2014, 48(增刊1): 160-164. DOI: 10.7538/yzk.2014.48.S0.0160
Citation: LI Meng, YIN Yan-peng, RONG Ru, XIANG Wei-ling. Development and Application of Reactivity Measurement System With Inverse Kinetic Method on Fast Neutron Critical Facility[J]. Atomic Energy Science and Technology, 2014, 48(增刊1): 160-164. DOI: 10.7538/yzk.2014.48.S0.0160

Development and Application of Reactivity Measurement System With Inverse Kinetic Method on Fast Neutron Critical Facility

More Information
  • Inverse kinetic method can be used for reactivity real time measurement and has special advantage for components reactivity scale, reactivity disturbance measurement and transient analysis on power reactor. In this paper, the reactivity measurement system with inverse kinetic method on fast neutron critical facility was developed, and arithmetic validation and performance analysis of this system were implemented. The results indicate that this system has high precision, fast response, high resolution and can be used conveniently. It is proved that this system can satisfy experiment requirements.
  • [1]
    贺仁辅,邓门才. 快中子临界装置和脉冲堆实验物理[M]. 北京:国防工业出版社,2012:424-428.
    [2]
    蒋宗炳. 数字反应性仪[M]∥中国核科技报告. 北京:原子能出版社,1996:466-474.
    [3]
    赵柱民,陈伟,缪正强. 脉冲堆反应性测量系统的研制[M]∥中国核科技报告. 北京:原子能出版社,2005:42-59.
    [4]
    黄礼渊,付国恩,李翔. 反应堆物理试验用便携式数字反应性仪的研制[J]. 核电子学与探测技术,2010,30(5):638-641.HUANG Liyuan, FU Guoen, LI Xiang. Development of portable digital reactivity meter for physical experiment on reactors[J]. Nuclear Electronics & Detection Technology, 2010, 30(5): 638-641(in Chinese).
    [5]
    尹延朋. CFBR-Ⅱ堆逆动态法实时测量技术研究[D]. 绵阳:中国工程物理研究院,2013.

Catalog

    Article views (158) PDF downloads (1162) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return