WANG Liang-ping, ZHANG Xin-jun, SUN Tie-ping, MAO Wen-ting. Development of Fast Shutter for Diagnosis System in Z-pinch Experiment[J]. Atomic Energy Science and Technology, 2016, 50(10): 1897-1901. DOI: 10.7538/yzk.2016.50.10.1897
Citation: WANG Liang-ping, ZHANG Xin-jun, SUN Tie-ping, MAO Wen-ting. Development of Fast Shutter for Diagnosis System in Z-pinch Experiment[J]. Atomic Energy Science and Technology, 2016, 50(10): 1897-1901. DOI: 10.7538/yzk.2016.50.10.1897

Development of Fast Shutter for Diagnosis System in Z-pinch Experiment

  • The debris or splashing mass will be produced by Z-pinch loads after the stagnation phase in Z-pinch experiments. The debris can arrive at the diagnosis devices and cause pollution to the optic units. In this paper, a kind of fast shutter based on the principle of electromagnetic induction was developed. The velocity, the discharge current and the shut-down time of fast shutter were analyzed based on the energy conservation principle and circuit model. The experimental results show that the velocity of fast shutter is nearly 19 m/s and the jitter of shut-down time is 85 μs. These experimental data show a good agreement with the calculation results.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return