ZHANG Jiaxin, WANG Chenglong, ZHAO Hanbing, ZHANG Dalin, SU Guanghui, QIU Suizheng, TIAN Wenxi. RELAP5 Modification and Verification for Lead-bismuth Fast Reactor[J]. Atomic Energy Science and Technology, 2021, 55(7): 1260-1267. DOI: 10.7538/yzk.2020.youxian.0500
Citation: ZHANG Jiaxin, WANG Chenglong, ZHAO Hanbing, ZHANG Dalin, SU Guanghui, QIU Suizheng, TIAN Wenxi. RELAP5 Modification and Verification for Lead-bismuth Fast Reactor[J]. Atomic Energy Science and Technology, 2021, 55(7): 1260-1267. DOI: 10.7538/yzk.2020.youxian.0500

RELAP5 Modification and Verification for Lead-bismuth Fast Reactor

  • To study the transient thermal-hydraulic characteristics of the lead-bismuth fast reactor, the system thermal-hydraulic analysis code RELAP5 was modified with lead-bismuth eutectic (LBE) properties and heat transfer models. Verification using the NACIE-UP facility and the CIRCE-ICE facility was completed. The calculation results show that the steady-state relative error and transient relative error for the NACIE-UP facility are within 2% and 5% respectively. And compared with other system thermal-hydraulic analysis codes, such as CATHARE, ATHLET, RELAP5-3D and RELAP5/MOD3.3 (modified), the relative deviation is within 10%. The steady-state relative error and transient relative error for the CIRCE-ICE facility are within 2% and 10% respectively. This code can meet the accuracy requirements of thermal-hydraulic analysis code of reactor system, and can be used as an effective tool for safety analysis of lead bismuth fast reactor.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return