HUANG Zhigang, ZHANG Yan, LU Xiaodong, PENG Chuanxin, ZAN Yuanfeng, ZHUO Wenbin, YAN Xiao. Experimental Study on DVI Line Break LOCA with Passive Safety System[J]. Atomic Energy Science and Technology, 2021, 55(11): 2021-2027. DOI: 10.7538/yzk.2020.youxian.0827
Citation: HUANG Zhigang, ZHANG Yan, LU Xiaodong, PENG Chuanxin, ZAN Yuanfeng, ZHUO Wenbin, YAN Xiao. Experimental Study on DVI Line Break LOCA with Passive Safety System[J]. Atomic Energy Science and Technology, 2021, 55(11): 2021-2027. DOI: 10.7538/yzk.2020.youxian.0827

Experimental Study on DVI Line Break LOCA with Passive Safety System

  • Small modular reactor ACP100 adopts passive safety system and modular design technology and can be applied in district heating, seawater desalination and nuclear power ship, etc. The passive safety design mainly includes automatic rapid depressurization system, passive emergency core cooling system and residual heat removal system. For validation and verification of design features of the ACP100, a series of LOCA experiments were finished on a scaled integral test facility in Nuclear Power Institute of China. The system comprehensive response characteristics under DVI line break condition were obtained based on the experimental data. The influential patterns between systems were obtained and the core cooling effect was preliminarily evaluated.
  • loading

Catalog

    Turn off MathJax
    Article Contents

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return