ZHANG Ting, DU Daiquan, ZHANG Wenhao, ZHUO Wenbin. Study on Parameter Sensitivity of Thermal-hydraulic Characteristic Experiment of Once through Steam Generator[J]. Atomic Energy Science and Technology, 2022, 56(11): 2365-2374. DOI: 10.7538/yzk.2022.youxian.0551
Citation: ZHANG Ting, DU Daiquan, ZHANG Wenhao, ZHUO Wenbin. Study on Parameter Sensitivity of Thermal-hydraulic Characteristic Experiment of Once through Steam Generator[J]. Atomic Energy Science and Technology, 2022, 56(11): 2365-2374. DOI: 10.7538/yzk.2022.youxian.0551

Study on Parameter Sensitivity of Thermal-hydraulic Characteristic Experiment of Once through Steam Generator

More Information
  • Once through steam generator (OTSG), with its advantage of compact structure and high power density, is widely used in petroleum and chemical industry, thermal power generation, and other industrial fields, and especially plays a vital role in integrated modular nuclear reactor. The narrow-channel heat transfer technology with double side heating is adopted in the doublepipe OTSG, which effectively reduces the thermal resistance of heat conduction and has higher heat transfer efficiency than the straight tube OTSG. In order to study the influence of the parameters under different operating conditions on the steam temperature of the double-pipe OTSG, a dual loop steam generator thermal-hydraulic characteristics test bench with high-temperature and high-pressure heat transfer medium in the primary side and low-temperature and low-pressure working medium in the secondary side was built. The flow diagram of test circuit, the scale and internal structure of the heat transfer tube of the test section, the setting of the experimental working condition range, and the experimental method were introduced in detail, and the uncertainty of the measured data was finally analyzed. The single variable method was used to study the influence of different parameters (average temperature of the primary circuit, load, steam pressure and feedwater temperature) on steam temperature under steadystate conditions, that is, the sensitivity analysis of operating parameters on steam temperature. The average temperature range of the primary circuit is from 282 ℃ to 307 ℃. The load range is from 20%FP to 120%FP. The steam pressure range is from 4.0 MPa to 6.0 MPa. The feed water temperature is between 40 ℃ and 160 ℃. The experimental results show that the lower the average temperature of the primary circuit is, the lower the steam temperature is. The closer to the saturation temperature of steam temperature, the greater drop is produced in steam temperature. The steam pressure has no effect on steam temperature under low load (20%FP-60%FP). However, the steam temperature decreases with the increase of steam pressure under high load (60%FP-120%FP), and the drop rate continues to increase. With the increase of load, there is a maximum steam temperature point. When the steam temperature is less than the peak value, the steam temperature rises slowly with the load. Conversely, when the steam temperature is greater than the peak value, the steam temperature drops sharply with the load. As for the influence of steam pressure, when the steam pressure increases, the peak value of steam temperature decreases. Accordingly, the load at the maximum steam temperature point also decreases. With the increase of feedwater temperature, the steam temperature decreases, but the reduction rate is very small compared with other parameters.
  • [1]
    秦长平. 紧凑式小型反应堆直流盘管蒸汽发生器热工水力研究[D]. 北京:中国科学院大学,2016.
    [2]
    毛宇飞,朱天宇,曹飞,等. 螺旋管内气液两相流摩擦压降计算方法新探[J]. 工程热物理学报,2016,37(3):556-561.
    MAO Yufei, ZHU Tianyu, CAO Fei, et al. A new method to calculate frictional pressure drop of gasliquid two-phase flow in helical coils[J]. Journal of Engineering Thermophysics, 2016, 37(3): 556-561(in Chinese).
    [3]
    孙中宁,阎昌琪,谈和平,等. 窄环隙流道强迫对流换热实验研究[J]. 核动力工程,2003,24(4):350-353.
    SUN Zhongning, YAN Changqi, TAN Heping, et al. Experimental investigation on forced convection heat transfer through narrow annulus[J]. Nuclear Power Engineering, 2003, 24(4): 350-353(in Chinese).
    [4]
    VINOD V, SIVAKUMAR L S, KUMAR V A S, et al. Experimental evaluation of the heat transfer performance of sodium heated once through steam generator[J]. Nuclear Engineering and Design, 2014, 273: 412-420.
    [5]
    CHUNG Y J, BAE K H, KIM K K, et al. Boiling heat transfer and dryout in helically coiled tubes under different pressure condition[J]. Annals of Nuclear Energy, 2014, 71: 298-303.
    [6]
    HWANG K W, KIM D E, YANG K H, et al. Study of flow boiling heat transfer and dryout characteristics at low mass flux in helically-coiled tubes[J]. Nuclear Engineering and Design, 2014, 273: 529-541.
    [7]
    SANTINI L, CIONCOLINI A, BUTEL M T, et al. Flow boiling heat transfer in a helically coiled steam generator for nuclear power applications[J]. International Journal of Heat and Mass Transfer, 2016, 92: 91-99.
    [8]
    SANTINI L, CIONCOLINI A, BUTEL M T, et al. Two-phase pressure drops in a helicallycoiled steam generator[J]. International Journal of Heat and Mass Transfer, 2008, 51(19-20): 4926-4939.
    [9]
    STATHAM B A, NOVOG D R. The effects of transient conditions on the onset of intermittent dryout during blowdown[J]. Nuclear Engineering and Design, 2017, 317: 118-132.
    [10]
    YANG S H, KIM S H, CHUNG Y J, et al. Experimental validation of the helical steam generator model in the TASS/SMR code[J]. Annals of Nuclear Energy, 2008, 35(1): 49-59.
    [11]
    JU H, ZHANG Y, HUANG Z, et al. Experimental and operational verification of the HTR-10 once-through steam generator (SG) heat-transfer and hydrodynamic features of the once-through steam generator[J]. Journal of Nuclear Science and Technology, 2004, 41(7): 765-770.
    [12]
    ANGLART H, PERSSON P. Experimental investigation of post-dryout heat transfer in annulus with spacers[J]. International Journal of Multiphase Flow, 2007, 33(8): 809-821.
    [13]
    TIAN Wenxi, MYINT A, QIU Suizheng, et al. Study on dryout point in vertical narrow annuli[J]. Nuclear Science and Techniques, 2005, 16(1): 53-58.
    [14]
    李晓伟,吴莘馨,张作义,等. 高温气冷堆示范工程螺旋管式直流蒸汽发生器工程验证试验[J]. 清华大学学报(自然科学版),2021,61(4):329-337.
    LI Xiaowei, WU Xinxin, ZHANG Zuoyi. Engineering test of HTRPM helical tube once through steam generator[J]. Journa of Tsinghua University (Science and Technology), 2021, 61(4): 329-337(in Chinese).
    [15]
    赵国正. 内部带旋转肋片的直流蒸汽发生器传热管热工水力性能实验研究[J]. 核动力工程,2015,36(3):24-27.
    ZHAO Guozheng. Performance test of a new type heat exchang tube with internally revolved rib in once-through steam generator[J]. Nuclear Power Engineering, 2015, 36(3): 24-27(in Chinese).
    [16]
    高刚,吴洪涛,黄素逸,等. 套管式蒸汽发生器沸腾传热实验研究[J]. 核动力工程,1996,17(4):332-336.
    GAO Gang, WU Hongtao, HUANG Suyi, et al. Experimental study on boiling heat transfer of steam generator in annuli tube[J]. Nuclear Power Engineering, 1996, 17(4): 332-336(in Chinese).
    [17]
    吴振宇,黄志超,徐光. 直流蒸汽发生器稳态流动沸腾实验研究[J]. 核科学与工程,2004,24(2):117-121.
    WU Zhenyu, HUANG Zhichao, XU Guang. Flow boiling experiment study of OTSG in steady state[J]. Chinese Journal of Nuclear Science and Engineering, 2004, 24(2): 117-121(in Chinese).
    [18]
    王明路. 螺旋管直流蒸汽发生器管内气液两相流动传热特性研究[D]. 上海:上海交通大学,2019.
    [19]
    毕力,李卫华. 基于壁面沸腾模型的套管式蒸汽发生器数值模拟[C]∥第十四届全国反应堆热工流体学术会议暨中核核反应堆热工水力技术重点实验室2015年度学术年会. 北京:[出版者不详],2015.
  • Cited by

    Periodical cited type(1)

    1. 黎磊磊,刘茂龙,倪嵩,王小文,刘利民,顾汉洋. 湿空气在全尺寸压水堆燃料组件中的自然循环特性试验及理论研究. 核技术. 2024(08): 159-168 .

    Other cited types(3)

Catalog

    Article views (125) PDF downloads (164) Cited by(4)

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return