NDZ-20医用电子直线加速器的注入系统

AN INJECTOR SYSTEM OF A NDZ-20 MEDICAL ELECTRON LINEAR ACCELERATOR

  • 摘要: 文章介绍了NDZ-20医用电子直线加速器的束流注入系统的结构和特性。电子枪为轰击型的皮尔斯电子枪。漂移管上的预聚焦线圈、偏掉线圈、导向线圈和束流前沿切割线圈用来实现对电子束的多种控制,实现加速器的ARC,ADC和BLC运用,以保证加速器运行的稳定性和可靠性,改善反馈加速器的能谱。

     

    Abstract: The structure and characteristic of an injector system of a NDZ-20 medicalelectron linear accelerator are described. A bombarded type of Pierce electron gunis used. There are pre-focusing coil, deflecting coil, steering coil and beam pulselead cutting coil in drift tube region. They control electron beam efficiently forARC, ADC and BLC of the accelerator. ARC and ADC can increace stability andreliability of accelerator operation, and BLC improve energy spectrum of the backfeed accclerator.

     

/