  • 摘要: 该工作用点源模拟的方法对Ge(Li)谱仪的效率进行了刻度,给出在240—1836 keV能区效率随点源位置的关系和体源效率的解析表达式。同时对体源的自吸收作了校正。把所得的效率用于对土壤样品天然γ放射性的分析,检验了方法的可行性。

     

    Abstract: The efficiency of a Ge (Li) spectrometer is calibrated with point source simulation method. The functional relation between the efficiency and point source positions and analytical formula of efficiency for volumetric sample are presented. The self-absorbtion of volumetric sample is also corrected. The feasibility of the method is tested by using the efficiency for analysis of natural γradioactivity in soil sample.

     

/