快中子束流稳定性的提高及旋转靶系统
THE IMPROVEMENT ON THE STABILITY OF NEUTRON BEAM AND THE ROTATIVE TARGET SYSTEM
-
摘要: 利用T(d,n)~4He反应作小角散射实验时,关联中子束的漂移成为影响实验稳定性的重要因素。文章给出了提高关联束稳定性和延长氚钛靶寿命的方法,详细介绍了旋转靶系统。Abstract: In the small angle scattering experiment using T (d, n)~4 He reaction, the kinematic shift of neutron beam associated with target aging is one of the hnportant factors on the experimental stability. The methods of improved stability of neutron beams and prolonged service life of T-Ti target are given. The rotative target system is described in derail.
-
-
[1] Benenson, R.E. et al., Nucl. phys., A212,147(1973). [2] Marshak, H. et al., phys. Rov., 150, 996(1966). -
期刊类型引用(1)
1. 韩志博,杨洪广,张建通,袁晓明,刘珊珊. 涂层及热处理对不锈钢薄壁管高温爆破性能的影响. 原子能科学技术. 2020(11): 2182-2187 . 本站查看