用屏栅电离室法和小立体角法测量样品中的~(238)U核素数目

Determination of ~(238)U Nucleus Number Using Grid Ionization Chamber Method and Small Solid Angle Method

  • 摘要: 用屏栅电离室法和小立体角法测量了高纯度U3O8样品中的2 38U核素数目。两种方法的探测效率虽相差近 50 0倍, 但得到的结果在实验误差范围内符合得很好。

     

    Abstract: Using the grid ionization chamber method and small solid angle method,the number of 238 U nucleus in the highly pure U 3O 8 sample is determined. Although the ratio of efficiency for the two methods is as high as 484, the results are in good agreement.

     

/