EDXRF法无损测定Ni-Mn-Co触媒合金组份

Non-destructive Analysis of Ni-Mn-Co Catalyzer Alloy by Energy Dispersive X-ray Fluorescence

  • 摘要: 用一系列已知Ni、Mn、Co含量的触媒合金片标样, 在能量色散X射线荧光 (EDXRF)谱仪上直接测量Ni Mn Co的特征X射线强度, 将Ni、Mn、Co含量与其特征X射线强度进行拟合, 建立工作曲线。测量未知样品时, 由测得的Ni、Mn、Co的特征X射线强度, 通过工作曲线求得Ni、Mn、Co含量。EDXRF法测量Ni Mn Co触媒合金中Ni、Mn、Co的含量范围分别为 60 %~ 85%、15%~30 %、2 %~ 8%, 对Ni、Mn、Co的测定精密度 (n =6)分别为 0 5%、2 %、5%。

     

    Abstract: The non destructive analysis method of Ni Mn Co catalyzer alloy by energy dispersive X ray fluorescence (EDXRF) is studied. A series of Ni Mn Co catalyzer alloy with known contents of Ni,Mn,Co are as standard samples, and the intensities of characteristic X ray of these standard samples are acquired by EDXRF spectrograph. A working curve is established by means of fitting the relation between the contents of Ni, Mn, Co and intensities of characteristic X ray from standard samples. When an unknown sample is determined, the contents of Ni, Mn, Co are obtained by filling the intensity of characteristic X ray of the sample measured by EDXRF spectrograph into the working curve. The measured range of content is 60 %~85 %,15 %~30 %,2 %~8 %, respectively for Ni, Mn and Co. The precision of this method is 0.5 %,2 %,5 %, respectively for Ni, Mn and Co.

     

/