反应堆压力容器钢早期疲劳损伤无损检测

  • 摘要: 正电子湮没线形参数测量和寿命测量对A50 8cl.3钢中位错密度反映是灵敏的。当疲劳损伤N/Nf≤ 10 %, 被测数据与损伤量有较好的对应关系。 5MHz和 15MHz超声衰减常数测量结果与上述情况类似。为验证无损检测结果, 进行了TEM观测。

     

    Abstract: Results indicate positron annihilation lineshape parameter S and lifetime measurements for dislocation density change in A508cl.3 steel are sensitive. When fatigue damage N/N f≤ 10 %, both S parameter and mean lifetime increase with N/N f value. Results for decay constant measured by ultrasonic waves at frequencies of 5 MHz and 15 MHz agree almost with above mentioned ones. Microstructures of fatigued specimens were examined by TEM to verify the results obtained by NDE.

     

/