合肥800 MeV电子储存环的色品测量与校正

  • 摘要: 介绍了合肥 80 0MeV电子储存环的色品测量与校正。采用改变二极铁电流方法测量了自然色品和采用改变RF频率方法测量了校正色品, 并对这 2种测量方法进行了理论分析和公式推导, 还给出了自然色品、校正色品以及六极铁电流对校正色品影响的测量结果

     

    Abstract: The measurement and correction of chromaticity for Hefei light source is introduced. The natural chromaticity is obtained by detecting the variation of the betatron tune with the main dipole field strength. The correction chromaticity is obtained by detecting the variation of the betatron tune with the RF frequency. The theoretic analysis and formula for the two methods is given. The measurement results of chromaticity are given.

     

/

返回文章
返回