高压充氘氚气体的金属系统研制
Study of Metal System for Filling D-T Gas Under the High Pressure
-
摘要: 描述了建造高压充氘氚金属系统的基本过程。 15MPa时, 系统漏率为 (3 7~ 4 8)× 10 -4Pa·L/s。经微球充气实验证实 :用该系统操作大量的氚 (2 8× 10 14 Bq)是极其安全、可靠的Abstract: The paper describes the essense process for building the metal system for filling D T gas under the high pressure. The system's leakage under the pressure of 15 MPa is ( 3.7~ 4.8 )×10 -4 Pa·L/s. The system is very safe and reliable proved by the experiment of filling gas to the microsphere, with handing a large quantity of tritium, e.g., 2.8×10 14 Bq.