超热电子磁谱仪的研制及标定
Development and Calibration of Hot Electron Magnetic Spectrometer
-
摘要: 研制了超热电子磁谱仪,介绍了谱仪的工作原理、设计思想、结构和主要技术指标。用137Csγ标准源对LiF热释光探测器(TLD)的离散性、重复性、灵敏度因子及线性吸收系数进行了测量。使用90Srβ源对谱仪进行了标定。Abstract: The hot electron magnetic spectrometer was developed and its principle, (designing) idea, structure and index were introduced. The derivation, repeatability, sensitivity and linear absorption coefficient (μ=1.31 mm~(-1)) for LiF TLD were measured by using a ~(137)Cs γ standard source. The spectrometer was calibrated by using a ~(90)Sr β standard source.