液体闪烁法测定硅胶相中Pu的α活度

Determination of α-Activity of Pu Adsorbed in Silica Gel With Liquid Scintillation Counting Analyzer

  • 摘要: 采用液体闪烁法测定硅胶相中负载的Pu,研究样品制备条件和测量参数等对分析结果的影响。在闪烁瓶中加入少于1 g负载Pu的干硅胶和10 mL闪烁液,搅拌5 min,用液体闪烁计数器测量300~800道窗口范围内的计数,可得到Pu的α活度。实验研究了HNO3、Fe、Zr、Nd等杂质对液闪测量的影响,并对液闪测量谱图进行了初步解析。

     

    Abstract: The liquid scintillation counting analyzer is used to determine the α-activity of Pu adsorbed in silica gel. The influences of preparation conditions and measuring parameters were studied. In order to determine the α-activity of Pu in silica phase, less than 1 g of silica gel was added into a 20 mL scintillation vial with 10 mL of cocktail. After 5 min of stirring, samples were measured by liquid scintillation analyzer. The activity of Pu in the vial equals to the total counts in energy window of 300-800 channel. The influences of HNO3, Fe, Zr, Nd on Pu analysis were studied. The formation of spectrogram was also preliminarily analyzed.

     

/

返回文章
返回