化学和容积控制系统下泄热交换器抗震分析

Seismic Analysis for Discharging Heat Exchanger of Chemical and Volume Control System

  • 摘要: 采用有限元方法对辽宁红沿河核电厂一期工程设备中的化学和容积控制系统(RCV)下泄热交换器进行了抗震计算分析,载荷包括自重、压力、温度、接管载荷和地震。根据RCC-M和ASME规范对计算结果进行评定。结果表明,RCV下泄热交换器的设计满足规范要求。

     

    Abstract: A finite element model for chemical and volume control system(RCV) discharging heat exchanger was set up to take seismic analysis by finite element method. The loads include weight, pressure, temperature, pipe load and earthquake. The result was evaluated by RCC-M and ASME. The results of evaluation indicate that the design of RCV discharging heat exchanger is satisfied with the requirement of standard.

     

/