  • 摘要: 为提高HTR-PM高温气冷堆蒸汽发生器的热交换效率并分隔冷热氦气的通路,必须在蒸汽发生器中设置绝热装置。在围绕换热管放置的钢制围筒上铺设一定厚度的绝热纤维,用多块覆盖板将绝热纤维压紧,在每块覆盖板中心与四角,用中间填充绝热纤维的螺栓将覆盖板定位并紧固,组成绝热层支撑结构。使用有限元方法对绝热层支撑结构在绝热材料压力、蒸汽发生器失压、地震等多种载荷的综合作用下的应力分布情况进行计算,计算结果表明:支撑结构在多种载荷的作用下仍能保持绝热层功能的可靠性与结构的完整性。

     

    Abstract: Thermal insulation device should be set in the steam generator to improve the efficiency of the heat exchange and compact the cold and hot helium. The thermal insulation fiber was laid on the steel cylinder around the heat exchange tubes, and packed firmly by steel plates. The plate was fixed in the middle and four corners by the bolts filled with thermal insulation fiber. The plates and bolts compose the supporting structure of thermal insulation layer. The stress distribution was calculated via finite element method (FEM) under the load of thermal insulation fiber pressure, loss of steam generator pressure and seism. The results show that the supporting structure of thermal insulation layer can keep its reliability and integrality under the definite loads.

     

/