  • 摘要: 中国实验快堆钢筋混凝土承压房间强度分析与评定是核安全局PSAR的遗留问题之一。本文对具有代表性的309#及813#两房间结构进行应力分析与评定,验证在事故工况下,房间能够保证其结构完整性。并在计算结果的基础上,得出房间所能承受的最大内压值。

     

    Abstract: The intensity analysis and assessment for China Experimental Fast Reactor reinforced concrete rooms, as one of the remanent issues of PSAR, were being paid great attention by the Nuclear Safety Bureau. In the paper, the stress analysis and assessments of room 309# and 813# were performed to ensure the structural integrity. On the base of the results, the maximal inner pressure that the rooms can support was deduced.

     

/