大亚湾核电站换料水箱底板渗漏分析与评估

Analysis and Evaluation of Leak of Refueling Water Storage Tank Bottom Plate for Daya Bay Nuclear Power Station

  • 摘要: 2006年9月发现大亚湾核电站2号机组换料水箱底板底部有微量水渗出。本工作通过地震分析、应力计算、断裂力学分析,对发现渗漏的大亚湾核电站2号机组换料水箱进行分析与评估。

     

    Abstract: The evaluation of leak of the refueling water storage tank bottom plate for Daya Bay Nuclear Power Station was finished by the seismic analysis, stress analysis and crack analysis.

     

/