  • 摘要: 高温气冷堆是第4代核能系统的重要堆型之一,由于其堆芯体积庞大、几何结构复杂,屏蔽计算难度较大。本工作使用三维SN程序TORT对10 MW高温气冷堆进行屏蔽计算,并用ANISN、MCNP程序进行校核。结果表明,TORT程序计算结果与ANISN、MCNP程序计算结果符合很好。

     

    Abstract: The hightemperature gascooled reactor is the important one in the generation Ⅳ nuclear system. Because of its large volume and complex structure, its shielding calculation is difficult. In this paper, shielding calculation of 10 MW HighTemperature GasCooled Reactor was carried out by using TORT code, and the result was compared with those from ANISN and MCNP code. The comparison results show that they meet well.

     

/