非能动余热排出热交换器数值模拟

Numerical Simulation of Passive Residual Heat Removal Heat Exchanger

  • 摘要: 用FLUENT软件对AP1000非能动余热排出热交换器进行非稳态数值模拟,研究其传热和流动特性。通过比较分析同一时刻不同位置温度场和流场的分布,以及不同时刻同一位置温度场和流场的变化,对该热交换器的传热过程和自然对流情况有了较深刻的认识,有助于分析其自然循环能力,为非能动余热排出系统的有效运行提供参考。

     

    Abstract: FLUENT software was employed to simulate the temperature-field and flow-field of AP1000 passive residual heat removal heat exchanger (PRHR HX), and investigate its heat-transferring and flow characteristics. Through comparative analysis of the distributions of temperature-field and flow-field in different locations at the same time, and the variations of temperature-field and flow-field in the same location at different time, heat-transferring process and natural convection situation of PRHR HX were understood deeply. It contributes to analyze the natural circulation capacity of PRHR HX, and provides some references for the effective operation of passive residual heat removal system.

     

/

返回文章
返回