Abstract:
According to the principle of coincidence theory, the specific activity of
241Am solution was determined on 4πα+4πγ counting standard device by γ efficiency extrapolation, and the problems of constant correction coefficients of self-absorption and scattering in α ionization chamber method were solved. The method was based on the alteration of detection efficiency when the height of elevator was altered, and the activity was obtained by γ fitting extrapolation according to detection efficiency. The results of more than 20 alpha radioactive sources by this method in our work are accordant with those of 2πα ionization chamber, and their uncertainties are improved to 0.4%.