α谱仪探测器和面源不同轴情况下几何因子的计算
Calculation of Geometric Factor on Condition for α Detector and Surface Source Being Not Coaxial
-
摘要: 使用投影法计算了α谱仪探测器和面源不同轴情况下的几何因子,并与实验结果进行了比较。结果表明,不同轴距情况下,α谱仪探测器和面源的几何因子与实验测量结果差异基本一致,对α谱仪刻度和实际测量时几何位置引起的不确定度的评估有参考价值。Abstract: A geometric factor was calculated using projection method on condition for α detector and surface source being not coaxial, and compared with experimental result. The differences between the geometric factor and experimental result are mainly consistent. The study is beneficial to α spectrometer calibration and uncertainty evaluation result from the geometric position in the routine measurement.