CT图像重建方法在半影成像中的应用

谢红卫, 祁建敏, 陈法新

谢红卫, 祁建敏, 陈法新. CT图像重建方法在半影成像中的应用[J]. 原子能科学技术, 2010, 44(增刊): 636-640. DOI: 10.7538/yzk.2010.44.suppl.0636
引用本文: 谢红卫, 祁建敏, 陈法新. CT图像重建方法在半影成像中的应用[J]. 原子能科学技术, 2010, 44(增刊): 636-640. DOI: 10.7538/yzk.2010.44.suppl.0636
XIE Hong-wei, QI Jian-min, CHEN Fa-xin. Application of Computer Tomography Image Reconstruction Method in Penumbral Imaging[J]. Atomic Energy Science and Technology, 2010, 44(增刊): 636-640. DOI: 10.7538/yzk.2010.44.suppl.0636
Citation: XIE Hong-wei, QI Jian-min, CHEN Fa-xin. Application of Computer Tomography Image Reconstruction Method in Penumbral Imaging[J]. Atomic Energy Science and Technology, 2010, 44(增刊): 636-640. DOI: 10.7538/yzk.2010.44.suppl.0636

CT图像重建方法在半影成像中的应用

Application of Computer Tomography Image Reconstruction Method in Penumbral Imaging

  • 摘要: CT图像重建方法和半影成像是两种传统的辐射图像诊断方式。将CT图像重建方法应用到半影图像数据处理中,探索出一种新的半影图像处理方法。在新的半影编码孔图像数据处理中,首次应用了与图像诊断系统点扩散函数无关的编码孔图像处理方法,解决了传统编码孔图像处理中由于图像诊断系统点扩散函数不确定带来的技术难题。在理论研究的基础上进行了半影模拟成像及图像重建,获得了理想的研究结果。

     

    Abstract: The CT (computer tomography) image reconstruction and penumbral imaging were conventional radiation image diagnostic methods. A novel penumbra image analyzing method, in which CT image reconstruction method was applied. A coded-aperture image analyzing method with no consideration of the system point spread function (PSF) was firstly presented, and technical difficulties in conventional code-aperture image analyzing due to uncertainty of the diagnostic system PSF were thus resolved. Based on the theoretical results, penumbra imaging and image reconstruction of a simple example are processed, and satisfactory results are achieved.

     

  • [1] CHRISTENSEN C R. First results of pinhole neutron imaging for inertial confinement fusion[J]. Review of Scientific Instrument, 2003, 74(5): 2 690-2 694.
    [2] WILSON D C, CHRISTENSEN C R, MORGAN G L, et al. Goals for and design of a neutron pinhole imaging system for ignition capsules[J]. Review of Scientific Instrument, 2003, 74(3): 1 705.
    [3] DELAGE O. Aperture design and numerical reconstruction technique requirements for high resolution imaging of neutrons in inertial confinement fusion (ICF)[J]. SPIE, 1998, 3460: 67-77.
    [4] CHEN Y W. Penumbral imaging of laser imploded target and its blind reconstruction[J]. IEEE, 1998, 757: 755.
    [5] DELAGE O, GARCONNET J P. Neutron penumbral imaging of inertial confinement fusion targets at Phebus[J]. Review of Scientific Instrument, 1995, 66(2): 1 205-1 209.
    [6] SHINSUKE F. Penumbral imaging for measurement of the ablation density in laser driven target[J]. Review of Scientific Instrument, 2002, 73(7): 2 588- 2 596.
    [7] XIAN Huahan. Reconstruction of penumbral imaging based on band filtering algorithm [J]. SPIE, 2007, 6787: 6 7872.
    [8] SHINYA N, CHEN Yen-Wei. A heuristic penumbral imaging technique for measurements of laser- produced plasma density profile[J]. Review of Scientific Instrument, 2002, 73(9): 3 198-3 204.
    [9] CHEN Y W. Blind reconstruction of X-ray penumbral images[J]. Review of Scientific Instru- ment, 1998, 69(5): 1 966-1 969.
    [10] KONG Xianglong. Restoration of pinhole images using Lucy-Richardson algorithm [J]. Acta Physica Sinica, 2006, 55(5): 2 364-2 370.
    [11] STEPHEN L, DARRYL D. Development of a dynamic spot size diagnostic for flash radiographic X-ray sources[C] ∥Pulsed Power Conference. [S. l.] : [s.n.], 2003.
    [12] VLADIMIR Y S. Measurements of micro-focus spot size (0.005-0.1) in X-ray tubs and lens[J]. SPIE, 2005, l5974: 1-8.
计量
  • 文章访问数:  733
  • HTML全文浏览量:  0
  • PDF下载量:  1120
  • 被引次数: 0
出版历程
  • 收稿日期:  1899-12-31
  • 修回日期:  1899-12-31
  • 刊出日期:  2010-10-20

目录

    /

    返回文章
    返回