气溶胶7Be活度浓度的测量方法及其应用

Measurement of 7Be Aerosol Activity Concentration and Its Application

  • 摘要: 用三层滤膜法测定7Be气溶胶的过滤效率,并对测量结果进行衰变修正,得到过滤效率为85.7%。同时,分析研究杭州附近气溶胶7Be活度浓度的年变化规律,得出主要原因是季节性降雨。

     

    Abstract: The filtration efficiency of 7Be aerosol was measured by the method of three-layer membrane. The filtration efficiency of 7Be aerosol is 85.7% with amendment on decay effect. The annual change regularity of 7Be aerosol activity concentration around Hangzhou area was analyzed, and it is concluded that the main reason is the seasonal rainfall.

     

/