ACME整体性能试验设施工作压力选取方案分析

Analysis on Working Pressure Selection of ACME Integral Test Facility

  • 摘要: 拟建造的先进堆芯冷却机理试验台架(ACME)是验证压水堆核电站非能动安全系统性能及其安全分析软件的整体性能试验设施。在介绍AP1000电站整体性能试验台架及其评价的基础上,分析了不同工作压力对试验的影响。重点阐述了ACME工作压力的选取方案及其特点,探讨了确定试验初始状态的方法。分析表明:选取9.3 MPa作为ACME的工作压力,涵盖了主要非能动系统工作的压力范围,具有等压等物性模拟非能动压水堆电站LOCA等事故工况的能力,是一个先进的非能动堆芯冷却整体性能试验设施设计方案。

     

    Abstract: An integral effects test facility, advanced core cooling mechanism experiment facility (ACME) was designed to verify the performance of the passive safety system and validate its safety analysis codes of a pressurized water reactor power plant. Three test facilities for AP1000 design were introduced and review was given. The problems resulted from the different working pressures of its test facilities were analyzed. Then a detailed description was presented on the working pressure selection of ACME facility as well as its characteristics. And the approach of establishing desired testing initial condition was discussed. The selected 9.3 MPa working pressure covered almost all important passive safety system enables the ACME to simulate the LOCAs with the same pressure and property similitude as the prototype. It’s expected that the ACME design would be an advanced core cooling integral test facility design.

     

/