Abstract:
As part of nuclear data library, neutron resonance parameter (NRP) plays a very important part in the application for national defense, industrial production and theoretical research. For some reason, there are no such research conditions for NRP in China, either experimental or theoretical. The analysis of NRP should base on experimental data, so a total cross-section measurement was done on the Pohang Neutron Facility (PNF), yielding a new set of transmission data of
169Tm below 100 eV, as well as a new set of NRP of
169T using SAMMY code. Taking all data collected for
169Tm NRP into consideration, a new set of
169Tm NPR was evaluated and recommended. After this work, the methodology and analyzing-flow for NRP evaluation were summarized, as a technological reservation for the future work.