  • 摘要: 结合三门和海阳核电厂厂用水系统的实际设计,考虑各运行工况下的运行要求,特别是系统布置相关性的影响,通过概率安全评价(PSA)建模确定了系统可用性情况及其相应的风险结果。基于风险分析的结果,为三门核电厂的设计缺陷提出了合理的改进建议方案,从而提高了该电厂的安全性和经济性。同时结合海阳核电厂的实际情况,分析结果认为基本无改进必要,充分体现了PSA对设计的支持和指导作用。

     

    Abstract: Probabilistic safety assessment (PSA) methodology was used to identify the availability of service water system (SWS) and the corresponding plant risk for Sanmen and Haiyang nuclear power plants, based on the actual design of SWS of the two plants, as well as the system operation requirements, especially the effect of the system layout. According to the results of the risk analysis, the reasonable modification suggestions on design deficiencies were provided for Sanmen Nuclear Power Plant, and the modification was unnecessary for Haiyang Nuclear Power Plant. It is shown that PSA functions as the support and instruction to the design.

     

/